Valves (146)
valves
Data provided by company: Exterior mounted leaflets with unique suture attachment allows for maximum leaflet excursion and larger EOAs Designed to provide excellent durability with the pericardial covered stent for…
Data provided by company: Identical in design to the Biocor™ stented tissue valve which delivers proven 20 year durability Low profile design provides optimal coronary ostia clearance Includes Linx…
Data provided by company: Identical in design to the Biocor™ stented tissue valve which delivers proven 20 year durability results Includes Linx AC Technology which is designed to improve…
Comments Surgery: Stented porcine valve, flexible stent reduces leaflet stress, adapts easily to annulus, low profile design (coronary ostia), 2 x 10-second rinse time References: Copyright St.…
Comments Surgery: Bileaflet design, rotation mechanism for intraoperative adjustment, size: 19-33mm (-37mm standard cuff), standard, expanded, PTFE or expanded PTFE cuff Comments Echocardiography: Published hemodynamic data for Masters HP mitral…
1 Data provided by company: Sewing cuff redesigned to facilitate supra-annular placement, allowing for an increase in orifice size for a given tissue annulus diameter Increased geometric orifice area (GOA), lower…
Comments Surgery: Bileaflet design, supra-annular placement, rotation mechanism for intraoperative adjustment, large effective orifice area, size: 19-33mm, Hemashield Graft, no pre-clotting, 12cm graft length Comments Echocardiography: There is no publisched…
Data provided by company: The graft is on a master standard valve sewed Minimizes the potential for patient prosthesis mismatch Expanded cuff - 15% more cuff than standard HP cuff…
Data provided by company: Allows placement of a larger pyrolytic carbon orifice, leading to an increased effective orifice area (EOA), lower pressure gradients and significantly improved hemodynamic performance The key…
Data provided by company: Over 25 years of long-term data for the Masters Series demonstrate low rates of thromboembolic events Standard valve first implanted in 1977 Pyrolytic carbon leaflets and…
More...
Data provided by company: Single digit gradients, even in sizes as small as 19 mm 1 Up to 84% orifice to annulus ratio 1 85 degree leaflet opening angle offers…
Data provided by company: The FlexCuff™ is flanged and more pliable than the standard cuff Single digit gradients, even in sizes as small as 19 mm Up to 84% orifice…
Comments Surgery: Stentless porcine valve, wide sewing ring, no-react treated Comments Echocardiography: Insufficient data on the hemodynamic performance References: Copyright by http://www.shelhigh.com/products-mitral.htm
Comments Surgery: Stentless porcine valve conduit, no-react treated, good hemodynamics Comments Echocardiography: Insufficient data on the hemodynamic performance References: Copyright by http://www.shelhigh.com/products-aortic.htm