Valves (146)
valves
Data provided by company: It is based on the ATS 3f® Aortic Bioprosthesis and a self-expanding Nitinol™ frame to hold the valve in its position Foldable into a small diameter,…
Comments Surgery: Bileaflet design, no cavity pivots, leaving no recesses or cavities where potential thrombi can form, continuous passive washing. Hemashield® Woven Double Velour Graft (low-porosity graft material) improves hemostasis…
Data provided by company: ATS AP means supra-annular Comments Surgery: Bileaflet design, no cavity pivots, leaving no recesses or cavities where potential thrombi can form, continuous passive washing References: Copyright…
Data provided by company: ATP standard means means intra-annular Comments Surgery: Bileaflet design, no cavity pivots, leaving no recesses or cavities where potential thrombi can form, continuous passive washing, intra-annular…
Data provided by company: ATS AP means supra-annular Comments Surgery: Bileaflet design, no cavity pivots, which means no recesses or cavities where a potential thrombus can form, continuous passive washing,…
Data provided by company: ATS AP means supra-annular, ATP standard means intra-annular Comments Surgery: Bileaflet design, no cavity pivots, which means no recesses or cavities where a potential thrombus can…
Comments Surgery: Stented porcine valve, polyester felt insert in the sewing ring provides strength with low suture drag Comments Echocardiography: No size-specific data on hemodynamic performance and no EOAi calculator…
Comments Surgery: Tilting disc design with a central strut, two phase movement of the disc, increased opening angle compared to other tilting disc designs Comments Echocardiography: Insufficient data on hemodynamic…
Comments Surgery: Stented porcine valve, polyester felt insert in the sewing ring provides strength with low suture drag, low stent profile Comments Echocardiography: Little size-specific data on hemodynamic performance and…
Comments Surgery: Tilting disc design with a central strut, two phase movement of the disc, increased opening angle compared to other tilting disc designs Comments Echocardiography: No EOAi calculator available…
More...
Comments Surgery: Reduced sewing-cuff (valve upsizing in small aortic root) Comments Echocardiography: No data on hemodynamic performance available. References: Copyright Medtronic
Comments Surgery: Stented porcine bioprosthesis, scalloped stent, designed for supra-annular implantation, Mosaic Ultra: reduced sewing-cuff (valve upsizing in small aortic root) References: Copyright Medtronic Rosenhek et al. Normal Values…
Data provided by company: Specifically designed for implant in a small aortic root, the ULTRA™ valve features a reduced sewing cuff offering surgeons the opportunity to upsize the valve. Comments Surgery:…
Data provided by company: The sewing ring of the Hancock II bioprosthesis is mounted flush with the inflow edge of the scalloped stent. This design allows the Hancock II aortic…